A-51 - Industrial Instrumentation Parts

A-51 - Industrial Instrumentation Parts

Part List

  1. Wrong sensor setting
  2. Check the sensor
  3. Check the sensor
  4. Set sensor properly
    E-27 Rs485 fault
    Data transmitting and
    receiving mistakes under the
    serial communication
  5. Check wiring
  6. Contact manufacturer
    E-28 Interference
    Improper operation caused
    by the surrounding EMI
    Use absorption circuit to
    eliminate the surrounding
    interference
    E-29 Buffer resistance is
    overload
    It occures when E-18
    appears frequently
    Refer to E-18
    E-30 Contactor fault
    1.Input & output is wired
    reverse 2.Power or driver
    has issue
    Check power or ask factory
    for help
    A-51 Back Electromotive Force
  7. Wrong motor parameters
  8. Self-learning with load
    leads to the low speed of
    self-learning
  9. The motor inertia causes
    incorrect identification
  10. Motor demagnetization
  11. Set motor parameters
    properly like rated
    frequency.rated speed. 2. Remove load when
    self-learning starts. 3. Set U3-59 according to
    the motor
    15 / 21
    Parameters Setting Table
    Note: “○”:The parameter can be modified in both standby and operating status. “●”: The parameter can’t be modified in operating status
    “◎”: The parameter is the actual detected and recorded value which can’t be modified. U0 Basic Function Parameters Group
    Function
    Code
    Description Set range Unit Default Modification
    Level
    Note
    U0-00 Pressure set 0.5~60 Bar 3.0 ○ U0-01 Start pressure
    set 0-U0-00 Bar 2.4 ○ Wakeup from
    standby when
    pressure is lower
    than PID set
    pressure
    U0-02
    Running
    Direction
    0:Forward
    1:Reverse
    2: Forbidden
    0 ○ Rotation direction
    can be changed
    or stopped by
    modifying the
    parameters
    U0-03 Sensor
    feedback type
    0: (0-10)
    1: (4-20)
    5: (4-20mA or 0- 10v),changed by
    U2-26
    V
    mA
    mA 1 ●
    0: V terminal
    1: C terminal
    5: C1 is 4-20mA
    for 4kw, below
    2.2kw C1=0-10V
    U0-04 Sensor range 0.0-60 Bar 10 ○ U0-05
    Pressure
    calibration
    factor
    (0~200) 100 ○ Display pressure
    is lower than
    actual
    pressure,increase
    the factor,on the
    contrary,decrease
    the factor
    U0-07
    Detection Time
    Of Maintaining
    Pressure
    3-6000 S 30 ○ U0-08 Sleep
    Frequency
    0.00-100 Hz 30.00 ● U0-09 Water leakage
    Factor
    0-10.0 Bar 0.5 ○ The larger the
    leakage,the
    bigger the value
    U0-10 Start and Stop
    controlling
    Mode
    0:keypad
    1:Terminal
    2:Communication
    control
    0 ○ U0-11
    Auto restart
    option when
    Power is on
    0: Invalid
    1: Restart when
    power on
    2:Command
    restart
    1 ○ U0-12 Auto-start
    delay
    0.1-100.0 S 10.0 ○
    16 / 21
    U0-13
    Frequency
    given
    0:U0-14
    1:PID
    2:Communication
    (slave comm.2)
    3.external
    controller (0-10v)
    4.external
    controller(4- 20mA)
    5.C1 (4-20mA)
    1 ○ U0-14 Hand input
    frequency
    0.00-200 Hz 50.00 ○ U0-15 Max.Frequency 5.00-200 Hz 50.00 ● U0-16 Upper limit
    Frequency
    5.00-200 Hz 50.00 ● U0-17
    Lower limit
    Frequency
    5.00-50 Hz 0 ● U0-18 Acceleration
    Time
    0.1-6000 S 4.0 ○ U0-19 Deceleration
    time
    0.1-6000 S 4.0 ○ U0-20 Stop Method
    0: Stop by
    deceleration
    1: Free-run Stop
    0 ○ U0-21 Percentage of
    start pressure
    0.0-100 80% ○ U0-22
    Parameters
    Initialization 0-9999 0 ●
    11: Reset to
    factory setting
    22:Remove faults
    U1 Pump Parameters Group
    Function
    Code
    Description Set range Unit Default Modification
    Level Note
    U1-00
    Water Shortage
    Detection
    Options
    0: Do not detect
    1:By current
    2:By Press. 3:By current &
    press. 4:Water shortage
    2
    Float switch is
    connected to
    DI3 and GND
    (COM),If no
    DI3,then use
    DI2 and GND
    (U2-12=0,U2- 11=11)
    U1-01
    Water Shortage
    Detecting
    Pressure
    0-60.0 Bar 0.5 ○ U1-02
    Water Shortage
    Detecting
    Frequency 0.00-100.0 Hz 45.00 ○ Only detecting
    water shortage
    when running
    frequency is
    over set
    frequency
    U1-03
    Delay Time For
    Water Shortage
    Detection
    0.1-999.9 S 50.0 ○ U1-04
    Detecting
    Current For
    Water Shortage
    Depending on
    motor type
    A ○ Applicable for
    U1-00:1&3
    U1-05 High Pressure 0-60.0 Bar 15.0 ○
    17 / 21
    Alarm Value
    U1-06
    Detection Time
    For High
    Pressure Alarm
    0.0-200.0 S 3.0 ○ U1-07
    Low Pressure
    Alarm Value
    0-60.0 Bar 0 ○ U1-08
    Detection Time
    For Low
    Pressure Alarm
    0.0-6000.0 S 60.0 ○ U1-09 Anti-Freezing
    Function
    0: OFF
    1: ON
    1 ○ U1-10 Running cycle
    for anti-freezing
    3-60000 Min 1500 ○ U1-11
    Running Time
    For Anti- Freezing
    0-6000 S 10 ○ U1-12
    Anti-Freezing
    Running
    Frequency
    0.00-100.00 Hz 30.00 ○ U1-13 Times of alarm
    auto reset 0-1000 200 ○ U1-14 Alarm auto reset
    time
    0-60000 Min 10 ○ U1-15 Alarm reset
    command
    0:OFF
    1:ON
    111 ● U2 Input & Output Parameters Group
    Function
    Code
    Description Set Range Unit Default Modification
    Level Note
    U2-00 Min.Input V
    value
    0.00-10.00 0.00 ○ U2-01
    Frequency For
    Min.Input V
    Value
    0.0-100.0 % 0.00 ○ U2-02 Max.Input V
    Value
    0.00-10.00 10.00 ○ U2-03
    Corresponding
    Frequency For
    Max.Input V
    Value
    0.0-100.0 % 100.0 ○ U2-04 V Filter Time
    Constant 0.01-10.00 s 0.05 ○ U2-05 Min.Input C
    Value
    0.00-20.00 4 ○ U2-06
    Corresponding
    Frequency For
    Min.Input C
    Value
    0.0-100.0 % 0.0 ○ U2-07 Max.Input C
    Value
    0.00-20.00 20.00 ○ U2-08
    Corresponding
    Frequency For
    Max.Input C
    Value
    0.0-100.0 % 100.0 ○ U2-09 C Filter Time
    Constant 0.01-10.00 s 0.05 ○ U2-10
    DI1 Multi functional
    Input Terminal
    0: No function
    1:Forward
    running
    1 ●
    11: Water
    Shortage Input
    18 / 21
    2:Reverse
    running
    3:Fault input
    4:Haste stop
    5:Reset
    6: PID pause
    7:Command by
    keypad
    8: Command by
    terminal
    9: Command by
    communication
    10:fault input
    when constant
    cose is chosen
    11: Water
    shortage input
    When D11 and
    GND are
    disconnected,water
    shortage alarm will
    be displayed on
    the screen. U2-11
    DI2 Multi functional
    Input Terminal
    0 ●
    U2-12
    DI3 Multi functional
    Input Terminal
    11 ● U2-14 Mo output
    0: No function
    1: running
    status
    2:fault
    3:FD
    4:FDT2
    5: Zero
    frequency
    running
    6:Lower limit
    frequency
    running
    7:Upper limit
    frequency
    running
    8:Standby
    9:Sleeping
    10: Reach
    temp.
    1 ○ U2-15 Relay1
    (TA,TB,TC) 2 ○ TA /TB normal
    closed, TA/TC
    open
    U2-16
    Relay2
    (TA1,TB1,TC1
    )
    1 ○ TA1 /TB1 normal
    closed, TA1/TC1
    open
    U2-17 Valid DI1 input
    delay
    0.0-3600.0 s 0.0 ○ U2-18
    Invalid DI1
    input delay
    0.0-3600.0 s 0.0 ○ U2-19 Valid DI2 input
    delay

Sourcing Information

For quotation, datasheet requests or bulk order inquiries:
- Email: candice@ausenist.com
- WhatsApp: +86 15959950473
- Please provide: exact brand, part number, quantity and application details.

PREVIOUS:d-24 - Process Equipment Parts

NEXT:A-01 - Industrial Maintenance Parts

Facebook

Twitter

Instagram

Pinterest

LinkedIn

+86-1595995***

candice20114

whatsapp

ausenist@ausenist.com

137651048