d-24 - Process Equipment Parts

d-24 - Process Equipment Parts

Part List

0.0-3600.0 s 0.0 ○ U2-20
Invalid DI2
input delay
0.0-3600.0 s 0.0 ○ Relay TA/TB/TC
U2-21
Valid DI3 input
delay 0.0-3600.0 s 0.0 ○ U2-22
Invalid DI3
input delay 0.0-3600.0 s 0.0 ○ U2-23
Mo output
delay 0.0-3600.0 s 0.0 ○ U2-24
relay output
delay
0.0-3600.0 s 0.0 ○ U2-25 Relay1 output
delay
0.0-3600.0 s 0.0 ○ U3 Advanced Parameters Group
Function
Code
Description Set Range Unit Default Modification
Level Note
19 / 21
U3-00 Baud rate for
communication
5:9600
6:19200
7:38400
6 ● U3-01 Address
3~5 for slave
drive. 1,2 for master
drive
1 ● U3-02 Alternation time 0-60000 min 480 ● U3-03 Auxiliary drive quantity 0-4 0 ● U3-04 Multi-pump control
method
0: master-slave
control
1:Synchronous
control
2.Evently
distributed
frequency for the
last two pumps
3.Only
changeover not
add pump
4.Master/slave
mode
0 ●
0: Switch pump
based on time
1: start and stop
with the same
frequency for all
the pumps
4:Change over
pump based on
address.
U3-05 Pump-adding delay 0.1-600.0 s 1.0 ● U3-06 Pump-reducing delay 0.1-600.0 s 0.1 ● U3-07 Delay of standy master
starts 0.1-30.0 s 20 ● U3-08 Standard baud rate
5: 9600
6: 19200
7:38400
5 ● U3-09
Standard protocol address 0-247
1 ● U3-10
Parameters displayed
under stop status
11=pressure
0= set frequency
1=busbar
voltage
11 ○ Only for V76
version
U3-11
Parameters displayed
under running status
15=pressure
0=running freq.
2=busbar
voltage 4=
output current,
13=temperature
15 ○ Only for V76
version
U3-12 Carrier Frequency
1-16 Motor
type ● U3-13 Torque Enhancement 0-20.0 %
Motor
type ● Depending on
motor
U3-17 Upper limit of
synchronous motor torque
50-200
150
U3-18
Protection for short circuit
on ground when power on
0: closed
1: ON 1
U3-19 Sleeping Delay Time 1.0-200.0 s 10.0 ○ U3-20 1 Proportionality Factor 0.0-50.0 15.0 ○ U3-21 1 Integral Time 0.1-100.0
s 1.5 ○
20 / 21
U3-26
2 Proportionality Factor 0.0-50.0
s 10.0
U3-27
2 Integral Time 0.1-100.0
S 2.0
U3-28
Diviation of PID change 0-100
% 60.0
U3-30 Detect value for
disconnected sensor
0.0-100.0 % 5.0
U3-31 Time for detecting
disconnection of sensor
0.0-3000.0
s 10.0 ○
0.0 represents
do not recognize
U3-32
Motor type 0: asynchronous
1:Permanent
magnet
synchronous
0 ● U3-33 Rated motor power 1-1000 KW ● Depending on
motor type
U3-34 Rated motor speed 1-10000
rpm ● Depending on
motor type
U3-35 Rated motor voltage 1-800 V ● Depending on
motor type
U3-36 Rated motor current 0.1-1000.0 A ● Depending on
motor type
U3-37 Rated motor frequency 5.00-200.0 Hz ● Depending on
motor type
U3-38 Output phase loss
protection option
0: OFF
1: ON
1 ○ U3-40 Motor overload gain
protection
20.0-1000.0 % 100.0 ○ U3-41 Quick current limit 0: OFF
1: ON
1 ○ U3-42 Overvoltage (stall speed)
Protection Voltage
120-150 % 130 ○ U3-43 Overcurrent Stall Speed
Gain
0-100.0
s 20 ○ U3-44 Overcurrent (stall
speed)Protection Current
100.0-200.0 % 160 ○ U3-45
Low Voltage Protection
Current
70.0-100.0 % 100.0 ○ U3-46 Auto fault reset times 0-20 3 ○ U3-47 Fault reset Interval time 0.1-100.0 s 10.0 ○ U3-54 Sleep section
0: OFF
1:ON
1 ● U3-55
Input phase loss
protection
0: OFF
1:ON
1 ●
d monitoring parameters group
d-00: Output frequency
d-03: Temperature
d-06: Feedback pressure
d-09:Accumulated power-on time(0- 65535H)
d-12:DI input
d-14:The second fault type
d-17: Current when faults happen
d-20: Fault time
d-21:Feedback pressure when faults
happen
d-01: Output current
d-04: Set pressure-current pressure
d-07:Set speed
d-10: V input voltage value
d-13:The first fault type
d-15:The third fault type
d-18: Bus voltage when fault occur
d-24: Output torque
d-27: C1 current
d-28: Version
d-02: Bus voltage
d-05: Set pressure
d-08:Accumulated
running time(0-65535H)
d-11:C input current
value
d-16:Fault frequency
d-19:Internal
Temperature when faults
happen
21 / 21

Sourcing Information

For quotation, datasheet requests or bulk order inquiries:
- Email: candice@ausenist.com
- WhatsApp: +86 15959950473
- Please provide: exact brand, part number, quantity and application details.

No previous

NEXT:A-51 - Industrial Instrumentation Parts

Facebook

Twitter

Instagram

Pinterest

LinkedIn

+86-1595995***

candice20114

whatsapp

ausenist@ausenist.com

137651048