E-27 - Industrial Hardware Parts
Part List
Digital input
Input voltage: 9~30V,input resistance: 10KΩ
V Analog input ,input : 0~10V, input resistance: 6.8KΩ
C,C1 Analog input, current: 4~20mA, input resistance: 500KΩ
GND Reference zero potential for 5V,10V,24V
10V Output voltage, current:0-10mA
MO Output terminal,external supply:0-24V,current:0-50mA
24V 24V output voltage
5V 5V output voltage
11 / 21
TA,TB,TC
TA1,TB1,TC1
Relay output : TA/TC open, TA/TB closed
TA1/TC1 open, TA1/TB1 closed
Contact capacity: AC250V/3A,DC30V/1A
S+, S- Pump communication
RS485+,RS485- For external monitoring
A01 Output alalog,0-10v
Control Board Terminal Diagram
Wiring diagram of power board and control board
12 / 21
Common Alarm Codes And Solutions
Alarm code Alarm Description Possible reasons Solutions
A-01 Water shortage protection
1. low inlet flow. 2. The power of drive is
bigger than that of
pump, Water pressure
below 0.5bar. 3. U1-01 value is set
too big.
1. Increase inlet
flow. 2. Modify U1-00
value to be 2. 3. Modify U1-01
value to a small
number. A-02 High water pressure protection
1. Actual pressure
exceeds 15bar
2. Transducer
malfunction,the
readout exceeds
15bar.
1. Modify U1-06
value to a
bigger number. 2. Replace the
failed
transducer . A-03 Low water pressure protection
1. Pressure below
0.5bar under the
normal running
status. 2. Pressure below
0.5bar ,the pump
rotates reversely. 3. Water consumption
is bigger than outlet
flow. 4. U1-08 value is set
too high.
1. Eliminate the air
in the pump. 2. Adjust the
rotation
direction. 3. Increase the
inlet flow
4. Replace with
bigger size
pump or reduce
water
consumption. 5. Change the U1- 08 value to a
small number. A-04 Low current protection
1. Incoming water
shortage. 2. The power of drive is
bigger than that of
pump. 3. U1-04 Value is set
too high
1. Increase
incoming water
2. U1-00 value is
modified as 2. 3. U1-04 value is
modified as a
small number. Fault Information And Trouble Shooting
Fault Code Fault Type Possible Reasons Solutions
E-01 Output Short circuit
1. Output short circuit or
connected to ground
2. Too heavy overload
1. Wiring inspection
2. Ask manufacturer for
help
E-02 Over current in speed
acceleration
1. Acceleration time is too
short. 2. Torque boost is too high
or V/F curve is not
applicable
1. Increase acceleration
time
2. Lower torque
boost,Increase voltage
to adjust V/F curve. E-03 Over current in speed
deceleration
Deceleration time is too short Increase deceleration time
E-04 Over current in running
Abrupt load change Reduce the fluctuation of
load
E-05 Software over current The same as E-01,E-02,E-03 The same as E-01,E-02,E- 03
13 / 21
E-06
Internal communication
problems
Hardware problems Ask manufacturer for help
E-07 Grounding faults
1. The output end of drive
or motor is connected to
ground
2. The drive’s input wire
and output wire is
connected together
1. Inspect wiring
2. Inspect if the motor
has aging problems. E-08 Over voltage in speed
acceleration
1. Too high input voltage
2. Frequently switch on and
off
Inspect the power and
voltage
E-09 Over voltage in speed
deceleration
1. Deacceleration time is
too short. 2. Abnormal input voltage
1. Increase deceleration
time
2. Inspect the power
voltage
3. Use new brake resistor
E-10 Over voltage in running
1. Abnormal input voltage
2. Returned energy load
1. Inspect the power
2. Use new brake resistor
E-14 underload
1. Virtual connection of
drive’s output wire
2. No load
1. Inspect the wiring
2. Inspect load
E-15 Drive overload
1. Too big load
2. Too short acceleration
time
3. Torch increases too high
or V/F curve not
applicable
4. Grid voltage is too low
1. Reduce load or use
big power drive
2. Increase acceleration
time
3. Lower torque,Increase
voltage to adjust V/F
curve. 4. Inspect grid voltage
E-16 Motor overload
1.Too big load
2.Too short acceleration time
3.Protection value is too
small
4.Torch increases too high or
V/F curve not applicable
1.Reduce load or use big
power drive
2.Increase acceleration
time
3.Increase overload
protection value
4.Lower torque,Increase
voltage to adjust V/F curve. E-17 Current detection fault
1. Breakdown of circuit or
detecting device. 2. Auxiliary power problems
Ask manufacturer for help
E-18 Undervoltage in running
1. Abnormal input voltage
2. Big load starts in power
grid
1. Inspect power voltage
2. Supply electricity
seperately
E-19 Open terminal external
devices fault
External devices
fault,Signal from input
end
Inspect the signal and its
related devices
E-20 Close terminal external
devices fault
External devices
fault,Signal from input
end
Inspect the signal and its
related devices
E-21 Drive overheating
1. Air passage blocked
2. The environment
temperature is too high
3. Fan failed
1. Clean up the air
passage
2. Decrease carrier
frequency
3. Change fan
E-22 Input phase loss
1. Input voltage phase loss
2. Input voltage is too low
1. Check input wires
connection
2. Check grid phase loss
E-23 Output phase loss Poor connection between Inspect wiring
14 / 21
drive and motor
E-24 Storage faults Hardware fault Contact manufacturer
E-25 Running time reaches set
time
Running time reaches set
time
Seek for service
E-26 PID feedback fault
1. PID feedback signal is
lost
2. Transducer is broken
3. Feedback information
does not meet setting
1. Check feedback
passage
2. Check transducer for
problems
3. Verify the correct
feedback to meet the
setting
E-27 Rs485 fault
Data transmitting and
receiving mistakes under the
serial communication
1. Check wiring
2. Contact manufacturer
E-28 Interference
Improper operation caused
by the surrounding EMI
Use absorption circuit to
eliminate the surrounding
interference
Parameters Setting Table
Note: “○”:The parameter can be modified in both standby and operating status. “●”: The parameter can’t be modified in operating status