RS485 - Factory Automation Components

RS485 - Factory Automation Components

Part List

740Series
Smart Water Pump Drive
User Manual
740drive allows your pump to work more efficiently,safely and smartly, reduce a large amount of
energy consumption and prolong the lifetime of your pumps.
740drive is made of high quality components and materials and adopts the latest microprocessor
technology.
This manual is issued for consumers to easily and properly operate the smart 740drive.The
information contained in this manual is subjected to change without prior notice.
Safety Precautions
In order to ensure the proper and safe use of 740drive series and avoid any possible damages on the
operator,drive or pump,please affirm to read carefully the below tips before installation and operation.
1 / 21
· Do not operate the equipment with power on, cut off the power and wait for at least 10 minutes before
wiring and inspection,or it would probably cause electric shock.
· The main circuit terminal must be connected to the power cable tightly or it would probably cause
damage on pump due to loose connection.
· Do not leave any other objects inside the drive,such as wire fragments,soldering tin,metal,etc. It would
cause electric short circuit to burn out the drive.
· Do not install capacity or piezoresistor on the output end of drive,or it will cause breakdown or fault on
the drive or even damage some critical components. Please remove it if there is any exsisting capacity
or piezoresistor
2 / 21
. Selection Table
Mod
1PH 220V in
3PH 220v out
e
Installing
Hole(mm
Size (mm Output
Curren
Power
t
)
)
740-2TR75A0 0.75KW
L
15 4A 0
W
102
H
118 Ø4
740-2T1R5A0 1.5KW 7A 150 102 118 Ø4
740-2T2R2A0 2.2KW 10A 150 102 118 Ø4
3PH 380V in
3PH 380v out
740-4TR75A0 0.75KW 2.1A 150 102 118 Ø4
740-4T1R5A0 1.5KW 3.8A 150 102 118 Ø4
740-4T2R2A0 2.2KW 5.1A 150 102 118 Ø4
740-4T004A0 4.0KW 9A 294 131 173 Ø5
740-4T5R5A0 5.5KW 13A 294 131 173 Ø5
740-4T7R5A0 7.5KW 16A 294 131 173 Ø5
740-4T011A0 11KW 25A 294 131 173 Ø6.5
740-4T015A0 15KW 32A 337 197 193 Ø6.5
740-
4T18R5A0 18.5KW 38A 337 197 193 Ø8.5
740-4T022A0 22KW 45A 337 197 193 Ø8.5
740-4T030A0 30KW 60A 348.5 227 171.5 Ø8.5
740-4T037A0 37KW 75A 348.5 227 171.5 Ø8.5
3 / 21
Technical Parameters
Controlling
Characteristic
Control Mode V/F control
Starting Torque 0.5Hz±100%
Speed Adjustable Range 1:100
Speed-holding precision ±1.0%
Overload Capability
150% rated current for 60s;180% rated
current for 1s
Acceleration/deceleration Time 0.1-3600s
Input&Output
Parameters
Start Frequency 0.01-10.00Hz
Input Voltage 220VAC±15%,380V±15%
Input Frequency Range 50/60Hz,fluctuation±5%
Output Voltage 0-rated input voltage
Output Frequency 0-200Hz
Peripheral Interface
Digital Input 3 way of digital terminal input
Analog Input
V: 0-5V
V (remote pressure gauge):0-10V
C(transducer): 4-20mA
C1(transducer):4-20mA
Replay Output 2 way output,pragrammable
Open Collection Output 1 way output,pragammable
Basic Functions
Command Running Channel
Three kinds of channels: 1.Operational
panel 2.Control terminal,3.Serial
communication port,choose 1 and 2 for
master drive and 3 for auxiliaries
Built-in PID
Advanced PID arithmetic to realize closed
loop control system
Stall Speed Control
Automatically limit current and voltage at
running period to prevent tripping due to
frequent overcurrent or overvoltage
Master and Auxiliaries connection
Extensible RS485 design,one drive in the
system can be master and controls the
other auxiliary drives (4 at most) to work by
communication mode,Master drive sends
PID feedback information to the auxiliary
drives and monitors status of auxiliaries in
real time.Any failure of the auxiliary drives
does not affect the others. Water Shortage Protection
If the drive detects the pipe pressure is
lower than the water shortage pressure set
value,the system stops working
automatically.After set period time,it
restarts automatically for specified times.If
pressure restores to normal,system works
normally,otherwise,system stops
automatically in case of idle running of
pump and prolongs pump lifetime to the
maximum extent. High Pressure Alarm When pressure exceeds set pressure,it
4 / 21
stops running automatically to avoid
damage on pipe network due to high
pressure. Automatic Energy-saving Running
A
lig
u
h
to
t
m
lo
a
a
t
d
ic
in
a
g
lly
to
lo
s
w
a
e
v
r
e
o
e
u
n
t
e
p
r
u
g
t
y
voltage under
Password Setting
4-bit password can be set with non-zero
numbers,Exit password setting interface
and the password will be valide in 1 minute. Parameters Locking
Define whether the parameter is locked in
running or stopped status in case of
misoperation. Use Condition
Installation
Installation should be executed under the
conditions of no direct
sunlight,dust,corrosive gas,inflammable
gas,oil mist,steam and water drop. Altitude
Lower than 1000m,service in derated
capacity above 1000m.Derate 1% capacity
every 100m increase in temperature. Environment Temperature
-10℃-+40℃,service in derated capacity for
40℃-50℃.Derate 4% capacity every 1℃
increase in height. Humidity ≤95%RH,no water condensation. Vibration <5.9m / S2(0.6G)
Keypad Description (quick use guide)
5 / 21
1.Indicator Lights
PRESS. Pressure setting is valid only when the light is on
RUN
Constant lighting means pump is running,while flickering means pump is in sleep
status
STOP Constant lighting means pump is in stop status. Online Flickering means inverter is in the multi-pump control mode
Manual Light-on indicates pump runs at a given frequency set by hand
Auto Light-on indicats pump is running in constant pressure mode
Low flow Light-on means pump is under protection against water shortage
Sleep Light-on means pump is sleeping .
2. Function button
Used to switch inverter from fixed mode to parameter setting mode
Used to set parameters and modify pressure values
1. In setting parameters,press shift to move the blink cursor

Sourcing Information

For quotation, datasheet requests or bulk order inquiries:
- Email: candice@ausenist.com
- WhatsApp: +86 15959950473
- Please provide: exact brand, part number, quantity and application details.

PREVIOUS:RS485 - Industrial Parts & Components

NEXT:SMW-AUTOBLOK

Facebook

Twitter

Instagram

Pinterest

LinkedIn

+86-1595995***

candice20114

whatsapp

ausenist@ausenist.com

137651048