MS220DA - Plant Engineering Components
Part List
costs. Fully equipped with both high-priority access to control and
status of the drive (PDO Communication) and access to all parameters
through acyclic data (SDO Communication). For interoperability the
..."
130B1107 VLT® Control Panel LCP 102 "Graphic operating unit LCP102 Illuminated graphic display with plain
text. Supports all languages and characters. Quick menu for brief
commissioning.Saving and copying parameter sets.Online help for each
function"
130B1108 VLT® 24V DC Supply MCB 107, uncoated Connect an external DC supply to keep the control section and any installed option alive during power failure. Enables full operation of the LCP (including the parameter setting) and all installed options without connection to mains.
130B1110 VLT® Relay Option MCB 105, uncoated "Relay extension for FC 100 and FC 300. Extension with 3 additional load relays
(changeover contacts), easy to retrofit thanks to modular technology.
Max. Load 240V AC (resistive): 2 A
Max. Load 240V AC (Cos Phi 0.4): 0.2 A
..."
130B1112 Sub-D9 Adapter kit, A1, A2, A3 "SUB-D9 plug adapter for FC 100 and FC 300. Allows the use of SUB-D9 connectors
at the Profibus DP interface."
130B1113 LCP Mounting Kit w/ graphical LCP102, 3m The kit includes graphical LCP, fasteners, 3m cable and gasket.
130B1114 LCP Mounting Kit w/ numerical LCP101, 3m The kit includes numerical LCP, fasteners, 3m cable and gasket.
130B1115 VLT® Encoder Input MCB 102, uncoated "Offers the possibility to connect various types of incremental and
absolute encoders. The connected encoder can be used for closed-loop
speed control as well as closed-loop flux motor control."
130B1117 LCP Mounting Kit, w/ no LCP The kit includes fasteners, 3m cable and gasket - There is no LCP included.
130B1118 VLT® Ext. Cascade Contr. MCO 101,unctd "CIRCUITOS MODULARES PARA CONTROLADORES DE VELOCIDAD DE MOTORES
ELECTRICOS"
130B1119 VLT® EtherNet/IP MCA 121, uncoated "MCA 121 EtherNet / IP interface
-Allows connection to EtherNet / IP based Automation systems via CIP (CommonInterface Protocol)
-2 port design reduces external components
..."
130B1120 VLT® Safe PLC I/O MCB 108, uncoated "Connection converter for FC 300 with control input for a safe stop. Allows secure connection.
Output modules with diagnostic pulse (Cross-circuit monitoring)."
130B1122 IP 21/Type 1 conversion kit, A2 Cover for housing size A2 MCF 101 NEMA1 / IP21
130B1123 IP 21/Type 1 conversion kit, A3 Cover for housing size A3, type 1 MCF 101 NEMA1 / IP21
130B1124 VLT® Control Panel LCP 101, numeric Numerical control unit for FC 100 and FC 300. Allows access to all device parameters. Quick menu for brief commissioning. Manual / auto switchover and alarm acknowledgment.
130B1125 VLT® General Purpose I/O MCB 101,unctd "MCB 101 - Advanced I / O option
Expands the number of freely programmable Control inputs and outputs around the following I / Os:
- 3 digital inputs opto-decoupled 0 - 24 V.
..."
130B1127 VLT® Resolver Input MCB 103, uncoated "Enables connection of a resolver to provide speed feedback from the
motor. Spring loaded connection."
130B1129 LCP Mounting Kit FC IP55/66, 8m The kit includes fasteners, 8m cable, gasket and a blind cover to ensure IP55/ 66 after the LCP has been mounted elsewhere. The 8m cable is open in one end and the connector block is included in the package. No LCP included.
130B1132 IP 21/Type 1 conversion kit, top, A2 "and bottom please order 130B1122
This is only the top part of the kit - If you need a kit with both top"
130B1133 IP 21/Type 1 conversion kit, top, A3 "and bottom please order 130B1123
This is only the top part of the kit - If you need a kit with both top"
130B1134 VLT® Motion Control MCO 305, uncoated "Integrated and programmable motion controller for VLT ® AutomationDrive FC 301 and FC 302
- Adds additional functionality and flexibility as it is a freely programmable..."
130B1135 VLT® PROFINET MCA 120, uncoated "MCA 120 PROFINET interface
-Supports operation on PROFINET network with extensive properties
-DCP support for easy setting u. Communication parameters via the PLC
- On Board web-Page with Drive Status
..."
130B1137 VLT® PTC Thermistor Card MCB 112, ctd "MCB 112 PTC - thermistor relay MS220DA In connection with ATEX certified explosion-proof
motors for full motor protection. Certified PTC sensors are the sole protection required.
..."
130B1143 VLT® Analog I/O Option MCB 109, unctd "I / O expansion for FC 100, through modular technology easy to retrofit. Analog inputs/outputs galvanically isolated. Expands the analog inputs / outputs by:
..."
130B1144 VLT® BACnet MCA 109, uncoated "Open communication protocol dedicated to building automation
- Efficient integration of all parts of building automation equipment
- BACnet: standard for building automation worldwide
..."
130B1152 VLT® Synchronizing Contr. MCO350,unctd "Expands the functional properties of the VLT® AutomationDrive in
synchronizing applications, and replaces traditional mechanical
solutions. Speed synchronizing. Position (angle) synchronizing with or
without marker correction. Online adjustable gear ratio. Online
..."
130B1153 VLT® Position Controller MCO351, unctd "Extends the functional characteristics of the frequency converter in
positioning applications
- Direct positioning via fieldbus, relative positioning, absolute
..."
130B1155 USB extension Cable, 350mm "USB extension kit for FC 300 cable length: 350mm for the housing size:
B2, C1 and C2 screw connection M 25"
130B1156 USB extension Cable, 650mm "USB extension kit for FC 300 cable length: 650mm for the housing size: B2, C1 and C2
screw connection M 25"
130B1157 oem costumer graphic lcp OEM version LCP102 w. no Danfoss branding.
Sourcing Information